The standard N-345 probe for the VID-345 flaw detector is designed to detect and determine the depth of cracks, incl. stress-corrosive, in metal ferromagnetic structures.
Search and assessment of damage can be performed under a layer of corrosion and / or protective coating. At the same time, the thickness of the existing corrosion layer and / or protective coating is measured. Allows to carry out measurements:
Under the influence of an alternating magnetic field generated by the N-345 sensor, eddy currents are excited in the controlled area of the product. Eddy currents in the crack area form stray magnetic fields, which are recorded by the sensor.
At the same time, using an alternating magnetic field, the distance from the sensor to the controlled metal surface is determined. Registration of these parameters makes it possible to measure the thickness of the protective coating or the depth of corrosion damage, as well as to identify and determine the depth of the crack regardless of the thickness of the protective coating or the depth of corrosion damage.
When ordering only the sensor, the device should be sent for retrofitting and adjustment.
Measurement parameters | |
Measurement range of cover thickness, mm | from 0 to 6 |
The error in determining the thickness of the protective coating, % | 10 |
Maximum cover thickness, mm | 10 |
Crack depth measurement range, mm | from 0,30 to 5,00 |
Depth measurement error, no more, mm | 0,2 mm + 0,1h (h - depth) |
Control parameters | |
Minimum opening of a detected crack, µm | 50 |
Minimum depth of detectable crack, µm | 200 |
Indentor | |
Material | high-strength ceramics |
Environmental protection | |
Body material | metal |
Dimensions and weight | |
Depth, mm | 25,0 |
Height, mm | 60,0 |
Width, mm | 25 |
Operating conditions | |
Operating temperature range, °C | from -15 to +40 |
There are no reviews for this product yet.. Write the first review.