Control sample MO-4 for MPD

Control sample MO-4 for MPDControl sample MO-4 for MPD
Control sample MO-4 for MPD, 1, 2 - surface defects; 3 - subsurface defects - three holes with a diameter of 2.5 mm, located from the cylindrical surface at a depth of 2, 3 and 4 mmControl sample MO-4 for MPD, 1, 2 - surface defects; 3 - subsurface defects - three holes with a diameter of 2.5 mm, located from the cylindrical surface at a depth of 2, 3 and 4 mm
1, 2 - surface defects; 3 - subsurface defects - three holes with a diameter of 2.5 mm, located from the cylindrical surface at a depth of 2, 3 and 4 mm
KROPUS
Price level: Retail
Retailcheckout at the office;
Online Starter*entry level benefits;
Online 1..5*five steps:
more orders - more benefits;
Online Wholesale*maximum benefit;
Online VIP*individual discount.

* valid only for orders placed on the site, according to the standard templates of contracts and accounts, it is mandatory to accept the Confidentiality Conditions for the information of an individual offer

17 424 руб.
delivery time to 10 days
Buy

The control sample MO-4 for MPD is designed to evaluate the performance of flaw detectors for induction and circular magnetization. Sample MO-4 is a disk 15 mm thick, 120 mm in diameter with a central hole 60 mm in diameter. On the cylindrical surface of the disk there is a surface defect in the form of a flat discontinuity of the material perpendicular to the generatrix of the cylinder (for working with induction magnetization flaw detectors).

On the control sample MO-4 there are also:

  • surface defect, the plane of which is parallel to the generatrix of the cylinder,
  • three subsurface defects in the form of holes 2.5 mm in diameter, located at different depths from the outer cylindrical surface (for working with circular magnetization flaw detectors).
Reviews

There are no reviews for this product yet.. Write the first review.

Отзыв

Overall score:
код

Thanks for your feedback!
The review will be published
after verification by the administrator

Close

Find out about the arrival

Close

Хотите скидку?

Хотите скидку?

Сначала войдите или зарегистрируйтесь!

Sign Up